Help

Define the two serial ports.

Interface Type (RS-285/422 only)
Choose between 2 wire RS-485 or 4 wire RS-422.

Serial speed
Select the serial transmission speed in Baud (bits per second).

Data bits
Select the number of serial data bits. Default setting is 8 data bits.

Parity bit
Select the parity bit settings. Default setting is disabled.
If enabled select Even or Odd parity.

Stop bits
Select the number of serial stop bits. Default setting is 1 stop bit.

Hardware flow control (RS-232 only)
Select if hardware flow contol (RTS/CTS) is used. Default setting is disabled.

Local port
Define the Port on which the serial gateway can be accessed using TCP.
Default: "10001" for RS-232, "10002" for RS-485/422
Enter "0" to disable TCP access and to free TCP handles for BCL application use

Disconnect Tout
Defines the time in seconds after which the TCP connection to the local serial port will be closed due to inactivity.
Enter "0" to disable the Disconnect Timeout (default).

Enter "1" to "255" to enable the Disconnect Timeout.