Help
NETWORK SETTINGS
Use SonicIP
If set to "yes", the device will announce its IP address over the audio output during device startup.
Default: "yes"
IP Address
Enter the 4 values of the desired device IP address e.g.:
"0.0.0.0" for automatic discovery (DHCP/BOOTP, IPzator, AutoIP)
"192.168.0.12" for an internal LAN
Default: "0.0.0.0"
Netmask
Enter the 4 values of the desired Static IP e.g.:
"0.0.0.0" for a default Netmask depending on the used IP Address.
"255.255.255.0" for a C class network
Default: "255.255.255.0"
Gateway IP Address
Enter the 4 values of the desired Gateway IP address e.g.:
"0.0.0.0" for no Gateway
"192.168.0.1" for a Gateway in a LAN
Note: The Gateway has to be set only when connecting to other devices over the WAN (through a router).
Default: "0.0.0.0"
Primary DNS
In this field you can give the desired primary and alternativ DNS IP address to be able to connect to URLs (e.g. www.radio.com).
Example: "195.186.1.111"
Default: "0.0.0.0"
Alternative DNS
In this field you can give the desired alternativ DNS IP address in case the primary DNS is not reachable.
Example: "195.186.4.111"
Default: "0.0.0.0"
Syslog Address
Destination address for syslog messages sent by the BCL program via the SYSLOG command. Set this to your syslog logging machine, if your syslog messages are recorded centrally.
If set to 0.0.0.0, syslog messages are broadcast.
Default: "0.0.0.0"
DHCP Host Name
Name of the device sent in DHCP request. If left empty, a name based on the device's MAC address is generated automatically. Enter up to 15 Characters.
Web Server Port
Defines the port where the web server of this device can be reached. If set to "0" the default HTTP port (80) is used.
SNMP System Name
SNMP MIB entry for system name (system.sysName.0)
SNMP System Location
SNMP MIB entry for system location (system.sysLocation.0)
SNMP System Contact
SNMP MIB entry for system contact (system.sysContact.0)
This parameter can be queried using any SNMP browser but can not be updated.
|
Help
STREAMING
RTP mode
"ON":Audio will be transmitted over RTP (used in VoIP systems)
"OFF":Audio will be transmitted using raw UDP protocol.
Default:"ON"
Streaming mode
"send always" will stream always to configured destination.
"send on I0/DI1" will stream if the I0 (Annuncicom 100/Legacy) or
DI1(Annuncicom 1000/Exstreamer 1000) is activated
Default:"send on I0/DI1"
Stream Audio to IP:Port
Set the destination where you want to stream the audio.
Destination IP could be unicast, multicast, broadcast address.
Its disabled if port is set to zero.
Default: "0.0.0.0:0"
Receive Audio from IP:Port
Set the source IP from where audio shall be accepted.
Source IP could be unicast,multicast cast address.
Set source IP to zero to receive audio broadcast.
Default: "0.0.0.0:3030"
Audio Buffer Delay
The RTP decoder keeps constant decoding latency within one frame accuracy.
Set the required delay in milliseconds.The delay value should be set large
enough to cope with network jitter (difference in packets delivery time) and
possible packet loss.Increase the value if you are experiencing audio dropout.
The lowest recommended setting is about 80ms for uLaw/ALaw 8kHz.
Default:"100 msec".
Relay Off Delay
Set this to activate relay when there is incoming audio.
If there is no audio for this configured interval,
relay shall be opened. To disable it,set it to 0.
Using this variable, the output relay activation can be prolonged,
which can be useful when the relay is being used to control, for example,
an amplifier. The relay off delay is needed when using MP3 encoding, where
the unpredictable nature of the compression means that it is not possible
to predict how long the audio will take to reach and transmit at the remote end.
Default: "1200msec"
|
Help
AUDIO SETTINGS
Input Source
Select the desired input source.
Default:"Line-in".
Encoding
Select desired audio encoding.
Default:"PCM/24kHz(16 bit)".
Volume
Choose between "0%" and "100%" in 5% steps.
Default: "50%"
Microphone Gain
Microphone gain dB, increase if your microphone is too faint, decrease if it's too loud or overdriven.
Default: "21dB"
A/D Amplifier Gain
A/D converter pre-amplification in dB. Increase if the audio signal too faint, decrease if it's too loud or overdriven.
Default: "0dB"
|
Help
CONTROL INTERFACES
TCP Control Port
Set the TCP control port.
Set it to 0 to disable TCP control interface.
Default:"12302"
UDP Control Port
Set the UDP control port.
Set it to 0 to disable TCP control interface.
Default:"12303"
Send IO Change to IP:Port
Set IP address and port number to send status changes to host.
Status changes are sent with UDP protocol.
If TCP command interface is connected, status changes are sent to
TCP remote host and its not sent to this configured host.
Default:"0.0.0.0:0"
Send SNMP trap to Host
Set IP address to send SNMP traps on input state and relay state
change.
Default:"0.0.0.0"
UDP Discovery Port
UDP port to discover devices running this application.
This port is fixed and is not configurable.
Do not set this port number in any other settings.
Default:"12301"
|
Help
SERIAL GATEWAYS
Gateway Protocol
Select communication protocol "UDP" or "TCP" to enable gateway functionality.
Further parameters are shown based on the selected mode.
Default: "TCP"
Connection Type "(TCP mode)"
"Active" Initiate connection with remote device.
"Passive" Listen for incoming connection.
Default: "Passive"
Destination IP
Defines IP address of remote device to establish TCP connection or to send UDP packet.
Default: "0"
Destination port
Defines the port number of remote device to establish a TCP connection or to send UDP packet.
Default: "0"
Local port "(TCP Mode)"
Defines the local port to listen on for an incoming TCP connection.
Default: "10000 for port 1 and 10001 for port 2"
Serial Port Settings
Baud Rate
Select the serial transmission speed ("300" to "230400" Baud).
Default: "9600"
Data Bits
Select "7" or "8" data bits.
Default: "8"
Parity
Select "no", "even" or "odd" parity.
Default: "no"
Stop Bits
Select "1" or "2" stop bits.
Default: "1"
Flow Control
Select the type of flow control:
RTS/CTS signals not used: "none"
RS232: "Software flow control(XON/XOFF)" or "Hardware flow control (RTS/CTS)"
RS485: "RS485 direction control"
Default: "none"
|
Help
SECURITY SETTINGS
Reset Function
Enable or disable the "Reset" function on the Reset button and on the WEB UI. In order to restart the device press the Reset button once.
Default: "enabled"
Factory Defaults
Enable or disable the "Factory Defaults" function on the Reset button. In order to revert all settings to factory defaults keep the Reset button pressed until the red LED starts blinking (approx. 10 seconds).
Default: "enabled"
Update Function
Enable or disable the WEB Update function of the device. If the Update function is disabled, the only way to update the firmware is to use the serial rescue.
Default: "enabled"
Set Password
This is visible as long as no password is set.
Enter a password (up to 25 characters) and hit the "Apply" button. After the restart you should close the browser window and open a new browser window. You will be asked to supply user name and password. The user name can be omitted but the password has to be supplied in order to see the web configuration.
Old Password / New Password
These fields are visible as long as a password is set.
To allow free access (clearing the password) enter the old password and leave the field "New Password" empty, then hit the "Apply" button.
After the restart you will not be asked for user name and password anymore.
To change the password enter the old password and enter the new password in the field "New Password", then hit the "Apply" button.
After the restart you will be asked for user name and password. The user name can be omitted but the new password has to be supplied in order to see the web configuration.
|